Commercial Duct Friction Loss Calculator

A fast commercial duct sizing tool and RTU air velocity calculator: enter CFM and a friction rate to get round equivalent diameter, rectangular duct dimensions, air velocity (FPM), and velocity pressure for field and design work.

Ad Space Placeholder — 728x90 Banner

Google AdSense / Ezoic integration point

System Parameters
Enter airflow and design friction targets to size the duct run.

in. w.g. per 100 ft

Duct Sizing Results
Round Duct Diameter
19"
Rectangular Duct Size
23" W × 15" H
Air Velocity
1,016 FPM
Velocity Pressure
0.064 in. w.g.

Calculations use the ASHRAE-derived approximation for round duct diameter at a given friction rate and equivalent rectangular dimensions. Always verify against local codes and project specifications.

Why use this tool
  • No sign-up required for calculations.
  • Works on desktops, tablets, and mobile.
  • Engineer-friendly friction rate sizing.
Get Commercial HVAC Quotes
Connect with local commercial HVAC partners for ductwork, RTUs, and full system quotes.

Quick Cost Estimator

Auto-detected from your ZIP code; change it any time.

Estimated installed cost — U.S. National Average

$140,000 – $220,000

$14.00 – $22.00 per sq ft

Rooftop Units (RTUs) with medium ducts (12"–24"). Regional index 1.00× (Baseline mechanical cost index); project-size factor 1.00×. Rough planning figure only — request a formal quote below.

View full project plan

By submitting, you agree to be contacted by a commercial HVAC partner about your project.

Duct sizing and friction loss FAQ

Common questions from engineers, HVAC technicians, and facility managers.

How does this commercial duct friction loss calculator work?

Enter design airflow in CFM and a target friction rate in inches of water gauge per 100 feet. The tool returns equivalent round diameter, rectangular duct dimensions, air velocity in FPM, and velocity pressure using the ASHRAE-derived friction chart approximation.

What friction rate should I use for commercial duct sizing?

Most commercial low-pressure supply systems are sized between 0.06 and 0.10 in. w.g. per 100 ft. Lower rates reduce fan energy and noise; higher rates save sheet metal and space.

Can I use it as an RTU air velocity calculator?

Yes. Enter the rooftop unit's design CFM and your friction target to get duct velocity in FPM. Keep main trunks near 1,200-1,800 FPM and branches under about 1,000 FPM to control noise.

Is this commercial duct sizing tool free?

Yes, it is free and requires no sign-up. It is intended for rapid field calculations by engineers, HVAC technicians, and facility managers.

Important Disclaimer

This calculator is for preliminary design guidance only. Final duct sizing, construction, and installation must be performed by qualified professionals and comply with applicable codes and standards.